精品国产亚洲国产亚洲,久热中文在线观看精品视频,成人三级av黄色按摩,亚洲AV无码乱码国产麻豆

上海壹僑國際貿(mào)易有限公司

主營產(chǎn)品: 德國工業(yè)備品備件,優(yōu)勢代理,PILZ繼電器,DOLD傳感器,GEMU蓋米閥/流量計(jì),ODU插頭,JUMO傳感器,VEM電機(jī),BUCHER閥門泵等等

10

聯(lián)系電話

13482106932

您現(xiàn)在的位置: 首頁> 技術(shù)文章 > narda HP-01

電動(dòng)葫蘆

滑線,碳刷

工具,夾具

卡盤,卡爪

過濾器,濾芯

連接器,接頭

電源

電機(jī),風(fēng)機(jī),馬達(dá)

軸承

泵,閥門

開關(guān)

繼電器,集電器

傳感器,編碼器

噴槍

風(fēng)機(jī),風(fēng)扇

氣缸

流量計(jì)

聯(lián)軸器

儀器儀表

打印機(jī)

備件

緊固件

導(dǎo)軌滑塊

電纜

刀柄

密封圈

離心機(jī)

測試軟件

點(diǎn)焊機(jī)

空調(diào)

AEG

DIEBOLD

SOMMER

HALDER

KUKA

LTN

NORELEM

OTT-JAKOB

PHOENIX

WURTH

PULS

SPECK

ELMESS

SCHENCK

Elaflex

EUCHNER

ETH

GEFRAN

HAIMER

TR

GEMU

KUEENLE

BEKO

SCHMALZ

IPE

Sera

HUMMEL

WEG

DAVTECH

BOLL

VIVOLO

ZANDER AACHEN

ENGLER

AVL

Schonbuch Electronic

FLUX

EOS

EMGR

ZAE

WALTHER

KRACHT

DMN

STAUBLI

KEB

PARKER

Harting

Messko

Vuototecnica

KENDRION

GEWEFA

ELFIN

GMW

HF JENSEN

Supfina

BEHLKE

zf

bielomatik

ENERFLUID

DREI BOND

MAAG

TEWS

RESY

LOVATO

Wachenhausen

SCHAD

STOTZ

Kraus & Naimer

SOLARTRON

buehler

TESTO

Delta

KOBOLD

RECHNER

H2WTECH

Optron

AKH

VEM

HIMMEL

傳感器

BIKON

NORFI

TBH

AGATHON

ESCHA

JAY Electronics

Gelbau

HANDTMANN

公司信息

聯(lián)人:
吳小姐
話:
021-69513882-819
機(jī):
13482106932
真:
86-021-69513882
址:
上海市嘉定區(qū)江橋鎮(zhèn)沙河路66號(hào)A幢201室
編:
網(wǎng)址:
鋪:
http://www.muquzhou.cn/st325143/
給他留言

narda HP-01

2018-10-10  閱讀(679)

Analysis of static and
time-variable magnetic
fields
Field exposure evaluation according to current
standards and regulations such as Directive
2013/35/EU for workplaces
Frequency-selective and wideband
measurement of magnetic fields from 0 Hz to
1000 Hz
Non-directional (isotropic) measurement with
orthogonally arranged Hall sensors
Extremely wide measurement range from 10 µT
to 10 T (dynamic range 120 dB)
FFT spectrum analysis and time response
display
Narrow band filter for standard compliant
measurement in the range 0 Hz to 1 Hz
Optical interface for control by PC or NBM-550
(not yet supported)
Magnetometer HP-01
NSTS 0517-E0332A  2 / 6 Subject to change without notice
APPLICATIONS
The Magnetometer HP-01 is a device for measuring static magnetic
fields and time-variable fields of frequencies up to 1000 Hz. Its main
application is in the measurement of high static fields with the aim of
ensuring the safety of personnel who have access to areas where such
fields are present. The possible risks are due to indirect effects, such as
the force exerted on ferromagnetic objects. As a consequence, hazards
can result from flying objects (projectile effect), or from the force exerted
on passive implants, or from functional impairments in active implants.
These must be identified and avoided. Risks can also occur due to
direct effects when the magnetic flux density is very high and movement
of the body within the field results in stimulation of sensory cells or nerve
cells. Exposure limit values are laid down in the ICNIRP Guidelines and
in the European Directive 2013/35/EU among other regulations. The
action  depend on the source of the hazard, ranging from relatively
low values (e.g. 0.5 mT for effects on active implants) up to very large
values of several Tesla. Typical areas where high fields are present are:
•  Magnetic resonance tomography (MRT)
•  Magnetic resonance spectroscopy (MRS)
•  Use and production of strong permanent magnets
such as lifting magnets
•  DC generators, particularly superconducting
•  DC motors, e.g. in railroads
•  Applications involving electric vehicles
•  Large industrial magnetic stirrers
•  Electrolysis used in the production of chlorine and aluminum
Figure 1: Particularly high static magnetic fields are
generated by magnetic resonance tomography (MRT)
Figure 2: Static magnetic fields are also present in DC
powered railroads
NSTS 0517-E0332A  3 / 6 Subject to change without notice
FUNCTION
The exposure level limits and action levels specified in guidelines and
standards cover a wide range of values. This would usually mean that
several different measurement probes would be needed in order to
achieve the necessary measurement dynamic range. The HP-01 easily
covers all these applications with its built in Hall effect sensors, which
have an unusually wide overall dynamic range from 10 µT to more than
10 T. Additional measurement probes are not needed. The orthogonal
arrangement of the sensors in the tip of the probe wand ensures that the
three spatial axes are captured completely, guaranteeing an isotropic
(non-directional) measurement. The sensors are located approximately
7 mm below the tip of the wand and are indicated by a clearly visible
groove.
The HP-01 is much more than just a magnetometer probe, however. It
includes a very powerful FFT analyzer that allows signal analysis in both
the time and the frequency domains. The fast signal processing allows
detailed, highly accurate gap-free analysis of the frequency spectrum.
The results can be displayed as a live spectrum, as a spectrogram
versus time, or as a three-dimensional waterfall diagram.
The “DC – 1 Hz” operating mode is a further special feature that is
particularly suitable for standard-compliant measurements according to
human safety standards. The limit values are usually specified for static
fields and variable fields with frequencies of up to 1 Hz. A finite impulse
response (FIR) filter used in the HP-01 captures just these frequency
components. The measurement is made using a high sampling rate and
delivers the corresponding wideband value for the 0 Hz to 1 Hz range,
which is required in order to demonstrate compliance with the limit
values. If required, more extensive analysis in the sub-Hertz region can
be performed from the time domain display of the instantaneous values.
This would not be possible in this way from the FFT analysis.
The HP-01 is operated using the HP01-TS software supplied, which is
compatible with all Microsoft Windows ® based PCs running Windows 7
or above. An optical cable with USB adapter links the measuring device
to the PC. The measurement can therefore be controlled from a safe
distance of up to 10 m. This can be extended to 50 m with cables,
available as options.
Figure 4: Main window with display of measurement
parameters and numerical result
Figure 3: Connector side of HP-01 with tripod adapter
attached
Figure 5: Time response display of a sine wave signal
in the sub-Hertz range in DC-1Hz operating mode
NSTS 0517-E0332A  4 / 6 Subject to change without notice
MEASUREMENTS USING A PC
The graphical user interface of the HP01-TS PC Software is arranged
very clearly and is easy to use. The main window (Figure 4) is displayed
when the program starts. The main settings such as measurement
range and frequency range are made in this window. The display area
continuously shows the numerical value of the magnetic flux density
measurement result, separately for the three spatial axes if required.
Click on the “Zero” button to trigger a zero adjustment that reduces
measurement uncertainty to a minimum. For this, the probe tip is placed
in the zero field chamber supplied, to exclude effects due to the earth’s
magnetic field or other fields. Three different modes enable selection of
frequency ranges for static fields (DC to 1 Hz), or for any single
frequency, or for band integration with settable frequency limits.
In addition to the numerical display of the measurement value, the time
response of the magnetic flux density can also be shown and evaluated
graphically. The graph shows the time response of the RMS value for
each of the three spatial axes and the isotropic total value. A constant
sine wave signal appears as a continuous horizontal line. In “DC - 1 Hz”
mode, the instantaneous value is shown instead of the RMS value, i.e. a
sine wave signal is also shown as a sine wave (Figure 5). This means
that even the frequency and amplitude of signal components below 1 Hz
can be determined.
FFT analysis represents the spectral distribution of the signal as an
amplitude spectrum (Figure 6). The spectrums are shown for the three
separate axes as well as for the isotropic total value. The frequency
range can be adapted in four stages by appropriate selection of the
“Span”. Two markers are provided to simplify result evaluation. It is also
possible to show the variation in the spectrum over time graphically,
either as a spectrogram (Figure 7) or as a waterfall diagram (Figure 8).
Figure 6: FFT analysis with display of amplitude
spectrum
Figure 7: FFT analysis with spectrogram display
Figure 8: FFT analysis with spectrum displayed as a
waterfall diagram
NSTS 0517-E0332A  5 / 6 Subject to change without notice
SPECIFICATIONS  a
HP-01 Magnetometer
Frequency range  DC (0 Hz) to 1000 Hz
Probe type  Magnetic (B) field
Field sensor
Triaxial orthogonal Hall effect devices (temperature compensated)
Simultaneous triaxial acquisition
Sensor area approx. 0.6 mm x 0.6 mm (10 T), approx. 0.15 mm x 0.15 mm (60 mT)
Measurement
range  b
Auto Range  ±10 µT to ±10 T  (units: mT, T, G, kG)
60 mT  ±10 µT to ±60 mT  (units: mT, G)
10 T  ±0,010 T to ±10 T  (units: T, kG)
Overload  20 T
Dynamic range (after zeroing)  120 dB (Auto Range)
Resolution
60 mT range  100 nT (Span 20 Hz and 30 Hz), 1 µT (Span 100 Hz and 1000 Hz)
10 T range  100 µT (Span 20 Hz and 30 Hz), 1 mT (Span 100 Hz and 1000 Hz)
Displayed average noise level (DANL)  c 10 µT
Flatness of frequency response  0.5 dB (typ.)
Expanded measurement uncertainty  d ±1 %
Temperature response  0.05 % / °C typ. (@ 0 Hz referred to 23°C)
Temperature and humidity meter  Internal sensor, temperature: -20 °C to + 55 °C, humidity: 5 % to 95 % RH
DC MODE
Frequency range  0 Hz to 1 Hz
Filter  FIR filter, cut-off frequency 1.0 Hz (-3 dB)
Result display Numerical result display and time plot (instantaneous value vs. time)
Reading update time  67 ms
Result type Instantaneous value, maximum hold, averaging (linear)
FFT MODE
Spectrum analysis Real-time gapless  e FFT
SPAN  (selectable) 20 Hz  30 Hz  100 Hz  1000 Hz
Frequency range  0 – 20 Hz  0 – 30 Hz  0 – 100 Hz  0 – 1000 Hz
Resolution  0.2 Hz  0.3 Hz  1 Hz  3 Hz
RBW (-3 dB)  0.8 Hz  1.2 Hz  4 Hz  10 Hz
Result display
• Spectrum (full Span), spectrogram, waterfall (3D)
• Numerical broadband value with selectable cut-off frequencies, time plot (RMS vs. time)
• Single frequency and time plot (RMS)
Reading update time  < 350 ms
Result type  Actual value (RMS), maximum hold, averaging (RMS)
OPERATION
Measurement control and display
Via PC (not included) and supplied software HP01-TS
or via NBM-550 (this function is not yet available)
Supported operating systems  Microsoft Windows ® 7, 8/8.1, 10
Data interface  Serial optical interface (115200 Baud) with optical converter to USB
a Unless otherwise stated, these specifications apply for the reference condition: ambient temperature 23 °C, relative air humidity 50 %
b For each single axis. Positive and negative at static fields (DC)
c After zeroing. DANL is frequency and SPAN depending. The specified performance is referred to 0 Hz and SPAN 20 Hz
d At static fields (DC)
e Overlapping for Span 20 Hz, 30 Hz and 100 Hz
NSTS 0517-E0332A  6 / 6 Subject to change without notice
® Names and Logo are registered trademarks of Narda Safety Test Solutions GmbH and L3 Communications Holdings, Inc. – Trade names are trademarks of the owners.
Narda Safety Test Solutions GmbH

HP-01 Magnetometer  Part number P/N
HP-01 Magnetometer Set DC-1kHz
Includes:
- HP-01 Basic Unit
- Zero Gauss Chamber
- AC/DC Battery Charger
- Cable, FO Duplex (1000 µm) RP-02, 10 m
- Cable, FO Duplex (1000 µm) RP-02, 25 cm
- O/E Converter USB, RP-02/USB
- Conical Tripod Support
- HP-01 / NBM Adapter
- Software CDROM including User’s Manual
- Certificate of Calibration
- Carrying Case
2405/101
OPTIONAL ACCESSORIES
Tripod, Non-Conductive, 1.65 m with Carrying Bag  2244/90.31
Tripod Extension, 0.50 m, Non-Conductive  2244/90.45
Cable, FO Duplex (1000 µm) RP-02, 2 m  2260/91.02
Cable, FO Duplex (1000 µm) RP-02, 5 m  2260/91.09
Cable, FO Duplex (1000 µm) RP-02, 20 m  2260/91.03
Cable, FO Duplex (1000 µm) RP-02, 50 m  2260/91.04



產(chǎn)品對(duì)比 產(chǎn)品對(duì)比 二維碼

掃一掃訪問手機(jī)商鋪

對(duì)比框

在線留言
99亚洲精品高清一二区| 被公侵犯人妻少妇一区二区三区| 日本成人在线一区中文字幕| 青青操成人版性视频| 操大美女逼射精视频| 精品一区二区三区成人免费视频| 日韩精品诱惑一区?区三区| 加勒比在线不卡一区二区观看| 国产一区精品在线| 亚洲国产精品一区亚洲国产| 亚洲综合网伊人中文| 女人182毛片a级毛片| 日韩激情视频在线看免费| 精品人妻一区二区三区日产乱码| 黑人大鸡巴双插美女| 亚洲一区二区三区日本在线| 欧美性爱撅臀插入啪啪啪| 中日美女毛5片一区二区三区| 国产午夜久久精品一区四虎| 一级风流国产片a级| 91污在线观看一区二区三区| 一区二中文字幕在线看国产一区| 夫妻性生活视频在线直播| 91久国产在线观看| 澳门一区二区免费下线观看| 正在播放 国产精品推荐| 日本亚洲欧洲一区二区| 欧美性爱撅臀插入啪啪啪| 亚洲天堂av一区二区在线观看| 视频一区视频二区制服丝袜| 精品人妻少妇一区二区三区不卡| 精品一区二区三区成人免费视频| a一级毛片免费高清在线| 一色道久久88加勒比一| 中文字幕乱码人妻一区二区三区| 999精品免费视频| 欧美一级特黄大片在线看| 女人被男人躁爽色欲国产| 久久精品国产亚洲av伦理| 日韩有码视频在线| 青青视频在线人视频在线|